FE Civil · Chapter 11 · 10–15 questions on the exam
FE Civil Water Resources & Env. practice problems
20 exam-style problems with worked solutions and the FE Reference Handbook page for each. Pick an answer to check it. No account needed.
Q1A triangular (V-shaped) roadside swale lined with grass (n=0.018) has symmetric side slopes of 1.5H:1V and carries flow at a depth of y=1.2m on a slope of S=0.0016. What is the discharge?
Worked solution
A triangular channel has no bottom width, so A=zy2=1.5(1.2)2=2.16 m2 and the wetted perimeter is both sloped sides: P=2y1+z2=2(1.2)1+2.25=4.327 m. RH=2.16/4.327=0.499 m. SI units so K=1.0: Q=(1/0.018)(2.16)(0.499)2/3(0.0016)1/2=3.02 m3/s. The 4.47 m³/s distractor uses P=2y (vertical depth only) instead of the sloped sides, inflating RH. The 0.95 m³/s distractor mistakes the triangular area for A=zy2/2=1.08 m2 (treating it as half base times height with the wrong base), which (together with the smaller RH) drops Q to about 0.95 m3/s. The 4.49 m³/s distractor uses K=1.486 (USCS) with SI inputs.
Flow area (triangular, z=1.5):
A=zy2=1.5(1.2)2=2.16m2
Wetted perimeter (two sloped sides):
P=2y1+z2=2(1.2)1+2.25=4.327m
Hydraulic radius:
RH=4.3272.16=0.499m
Manning's equation (SI, K=1.0):
Q=0.0181.0(2.16)(0.499)2/3(0.0016)1/2
Compute:
Q=55.56×2.16×0.629×0.04=3.02m3/s
FE Reference Handbook 10.6, p. 303
Q2A corrugated metal culvert (n=0.024) with a diameter of D=4ft flows exactly half full on a slope of S=0.005. What is the discharge?
Worked solution
For a pipe flowing half full: A=πD2/8=π(4)2/8=6.283 ft2 and P=πD/2=2π=6.283 ft, so RH=A/P=1.0 ft. The neat result is that a half-full pipe has the SAME hydraulic radius as a full pipe (D/4=1.0 ft), but only half the flow area. Q=(1.486/0.024)(6.283)(1.0)2/3(0.005)1/2=27.5 cfs. The 55.0 cfs choice uses the full-pipe area (πD2/4), doubling the answer. The 43.7 cfs choice uses RH=D/2 instead of D/4. The 18.5 cfs choice forgets the K=1.486 factor for USCS units.
Flow area (half full):
A=8πD2=8π(4)2=6.283ft2
Wetted perimeter (half circumference):
P=2πD=2π=6.283ft
Hydraulic radius:
RH=PA=6.2836.283=1.0ft=4D
Manning's equation (USCS, K=1.486):
Q=0.0241.486(6.283)(1.0)2/3(0.005)1/2
Compute:
Q=61.92×6.283×1.0×0.0707=27.5ft3/s
FE Reference Handbook 10.6, p. 303
Q3Water flows at Q=20m3/s in a rectangular channel B=4m wide at a depth of y=2.5m. What is the specific energy of the flow?
Worked solution
Specific energy is depth plus velocity head: E=y+v2/(2g). First the velocity: v=Q/A=20/(4×2.5)=2.0 m/s. Then v2/(2g)=4/(2×9.81)=0.204 m. E=2.5+0.204=2.70 m. The 2.50 m choice reports only the depth, forgetting the velocity head entirely. The 2.91 m choice uses v2/g (omitting the factor of 2 in the velocity head). The 0.20 m choice reports only the velocity head, forgetting to add the depth.
Velocity:
v=ByQ=4×2.520=2.0m/s
Velocity head:
2gv2=2(9.81)(2.0)2=0.204m
Specific energy:
E=y+2gv2=2.5+0.204=2.70m
FE Reference Handbook 10.6, p. 301
Q4A hydraulic jump in a wide rectangular channel has an upstream (supercritical) depth of y1=0.5m and a downstream (subcritical) conjugate depth of y2=2.5m. What is the energy lost across the jump?
Worked solution
When both conjugate depths are known, the energy loss has a closed form: ΔE=(y2−y1)3/(4y1y2). ΔE=(2.5−0.5)3/(4×0.5×2.5)=(2.0)3/5.0=8/5=1.60 m. The 6.40 m option omits the factor of 4 in the denominator: (2.0)3/(0.5×2.5)=6.40. The 2.00 m option just reports the depth difference y2−y1=2.0. The 4.00 m option drops y2 from the denominator: (2.0)3/(4×0.5)=4.00.
Energy loss across a hydraulic jump:
ΔE=4y1y2(y2−y1)3
Substitute:
ΔE=4(0.5)(2.5)(2.5−0.5)3
Compute:
ΔE=5.0(2.0)3=58=1.60m
FE Reference Handbook 10.6, p. 303
Q5An 8-inch ductile iron main (C=140) is 1,200ft long and carries Q=1.8ft3/s flowing full. Using Q=k1CARH0.63Sv0.54 with k1=1.318 and RH=D/4, what is the head loss over the full length?
Worked solution
Convert D=8 in.=0.667 ft, so A=π(0.667)2/4=0.349 ft2 and RH=D/4=0.167 ft. Rearrange Hazen-Williams for the slope: Sv=[Q/(k1CARH0.63)]1/0.54. Plugging in: Sv=[1.8/(1.318×140×0.349×0.1670.63)]1/0.54=0.01073. Head loss =SvL=0.01073×1,200=12.9 ft. The 5.7 ft choice uses RH=D/2, overstating RH and lowering the required slope. The 24.0 ft choice uses the rougher 20-year cast iron value C=100. The 29.1 ft choice uses the SI coefficient k1=0.849 instead of the USCS 1.318.
Q6A 90-degree V-notch weir at a stream gauging station passes a discharge of Q=8.0ft3/s. Using the USCS coefficient C=2.54, what is the head H above the notch?
Worked solution
The 90-degree V-notch formula is Q=CH5/2, so H=(Q/C)2/5=(8.0/2.54)0.4=(3.150)0.4=1.58 ft. The 2.01 ft choice uses the SI coefficient C=1.40 instead of the USCS 2.54. The 2.15 ft choice uses the rectangular weir exponent 3/2, solving H=(Q/C)2/3=2.15. The 3.15 ft choice forgets the exponent entirely, computing H=Q/C=3.15.
90-degree V-notch weir (USCS):
Q=CH5/2
Solve for the head:
H=(CQ)2/5=(2.548.0)0.4
Compute:
H=(3.150)0.4=1.58ft
FE Reference Handbook 10.6, p. 303
Q7A watershed is 70 percent residential (CN=80) and 30 percent open space (CN=60) by area. A storm delivers P=3.5in. of rainfall. Using the area-weighted composite curve number and the SCS method, what is the runoff depth?
Worked solution
First find the composite curve number weighted by area: CN=0.70(80)+0.30(60)=56+18=74. Then S=1000/CN−10=1000/74−10=3.51 in. Check: 0.2S=0.70 in. <P=3.5 in., so runoff occurs. Q=(P−0.2S)2/(P+0.8S)=(3.5−0.70)2/(3.5+2.81)=(2.80)2/6.31=7.84/6.31=1.24 in. The 1.94 in. distractor omits the initial-abstraction subtraction in the numerator, using P2/(P+0.8S)=1.94. The 2.80 in. distractor reports the un-squared numerator (P−0.2S)=2.80. The 3.50 in. distractor assumes all rainfall becomes runoff.
Composite (area-weighted) curve number:
CN=0.70(80)+0.30(60)=74
Maximum retention:
S=741,000−10=3.51in.
Check initial abstraction:
0.2S=0.70in.<P=3.5in.✓
SCS runoff equation:
Q=3.5+2.81(3.5−0.70)2=6.31(2.80)2=1.24in.
FE Reference Handbook 10.6, p. 296
Q8A storm drain inlet must be sized for a peak design flow of Q=90cfs. The contributing area has a runoff coefficient C=0.55 and the design rainfall intensity is I=3.0in./hr. Using the Rational Method, what drainage area does this represent?
Worked solution
Rearrange Q=CIA to solve for area: A=Q/(CI)=90/(0.55×3.0)=90/1.65=54.5 acres. The Rational Method units work out directly (1 acre-in./hr ≈ 1 cfs), so no conversion is needed. The 16.5-acre choice multiplies by C instead of dividing: QC/I=90(0.55)/3.0=16.5. The 30.0-acre choice ignores C entirely: Q/I=90/3.0=30. The 163.6-acre choice forgets the intensity: Q/C=90/0.55=163.6.
Rearrange the Rational Method:
A=CIQ
Substitute:
A=0.55×3.090=1.6590
Compute:
A=54.5acres
FE Reference Handbook 10.6, p. 296
Q9A 1-hour unit hydrograph has ordinates (in cfs) of 0,100,300,150,0 at t=0,1,2,3,4 hours. A storm produces 2in. of excess rainfall in the first hour followed by 3in. in the second hour. Using superposition, what is the peak of the direct runoff hydrograph?
Worked solution
Each rainfall pulse produces its own scaled, lagged unit hydrograph; you add the two. The 3-inch pulse starts one hour later than the 2-inch pulse. Tabulate hour by hour and sum. The maximum occurs at hour 3: from the 2-inch pulse 2×150=300, plus from the lagged 3-inch pulse 3×300=900, totaling 1,200 cfs. The 1,500 cfs choice simply scales the UH peak by the total depth (5×300=1,500), which is wrong because the two pulses do not peak in the same hour. The 900 cfs choice counts only the 3-inch pulse on the UH peak (3×300). The 600 cfs choice counts only the 2-inch pulse peak (2×300) and ignores the lagged 3-inch pulse.
Pulse 1 (2 in.) scaled UH peaks at hour 2:
2×300=600cfs at t=2
Pulse 2 (3 in.) is lagged 1 hour; its UH peak lands at hour 3:
3×300=900cfs at t=3
At hour 3, add both contributions:
pulse 12×150+pulse 23×300=300+900
Peak direct runoff:
Qpeak=1,200cfs
FE Reference Handbook 10.6, p. 298
Q10A storm produces a direct runoff volume of 1,500acre-ft from a watershed with a drainage area of 6,000acres. What is the equivalent depth of direct runoff over the watershed?
Worked solution
Runoff depth is volume divided by area, then converted to inches. In consistent units, depth =V/A=1,500/6,000=0.25 ft. Convert to inches: 0.25×12=3.0 in. The acre cancels between acre-ft and acres, leaving feet, which you multiply by 12. The 0.25 in. choice stops at 0.25 ft but mislabels it as inches (forgot the factor of 12). The 6.0 in. choice doubles the result by an arithmetic slip. The 36.0 in. choice multiplies by 12 twice (applies 144 instead of 12).
Depth in feet (acres cancel):
d=AV=6,000acres1,500acre-ft=0.25ft
Convert to inches:
d=0.25ft×12ftin.=3.0in.
FE Reference Handbook 10.6, p. 298
Q11Water seeps horizontally through a confined sand layer beneath a dam. The hydraulic conductivity is K=4×10−5m/s, the flow cross-section is A=300m2, and the head drops 6m over a flow path length of 120m. What is the seepage discharge in cubic meters per day?
Worked solution
Darcy's law gives the volumetric flow: Q=KAi, where the gradient is i=dh/L=6/120=0.05. So Q=(4×10−5)(300)(0.05)=6.0×10−4 m3/s. Convert to per day: 6.0×10−4×86,400=51.8 m3/day. The 0.17 m3/day choice forgets the cross-sectional area, using Ki only (times 86,400). The 6,221 m3/day choice forgets to divide the head drop by the path length, using i=6 instead of 0.05, inflating Q by 120 times. The 2.6 m3/day choice mishandles the area, dividing by it instead of multiplying.
Hydraulic gradient:
i=Ldh=1206=0.05
Darcy discharge:
Q=KAi=(4×10−5)(300)(0.05)=6.0×10−4m3/s
Convert to per day:
Q=6.0×10−4×86,400=51.8m3/day
FE Reference Handbook 10.6, p. 298
Q12A well in an unconfined aquifer (K=6×10−4ft/s) is pumped at Q=0.8ft3/s. At an observation point r2=300ft away the saturated thickness is undisturbed at h2=80ft. Using Dupuit's formula, what is the water level h1 at the well face (r1=1ft)?
Worked solution
Rearrange Dupuit, Q=πK(h22−h12)/ln(r2/r1), to solve for the well-face head: h1=h22−Qln(r2/r1)/(πK). The log term: ln(300/1)=5.70. So h1=802−0.8(5.70)/(π×6×10−4)=6400−2419=3981=63.1 ft. The drawdown is about 17 ft. The 73.1 ft choice uses log10 instead of the natural log. The 72.0 ft choice uses 2π (the confined Thiem coefficient) instead of π. The 80.0 ft choice forgets to apply any drawdown and just reports the undisturbed level.
Dupuit's formula solved for the well-face head:
h1=h22−πKQln(r2/r1)
Evaluate the log term:
ln(1300)=5.70
Substitute:
h1=802−π(6×10−4)0.8(5.70)=6,400−2,419
Compute:
h1=3,981=63.1ft
FE Reference Handbook 10.6, p. 299
Q13A wastewater sample has an ultimate BOD of L0=320mg/L and a decay rate of k=0.18day−1 (base e). What is the BOD remaining (not yet exerted) after 4 days?
Worked solution
BOD remaining is the organic matter not yet decomposed: Lt=L0e−kt=320e−0.18×4=320e−0.72=320(0.487)=155.8 mg/L. Note the BOD exerted (L0(1−e−kt)=164.2) plus the remaining (155.8) sum to the ultimate 320. The 164.2 mg/L choice gives the BOD exerted rather than remaining. The 57.6 mg/L choice applies kt as a percentage (0.18×4=0.72, then 320×0.18=57.6), a formula confusion. The 320 mg/L choice reports the ultimate BOD, as if no decay had occurred.
BOD remaining (decay form):
Lt=L0e−kt=320e−0.18×4
Evaluate the exponent:
e−0.72=0.487
BOD remaining at 4 days:
Lt=320×0.487=155.8mg/L
FE Reference Handbook 10.6, p. 327
Q14Downstream of an outfall, the deoxygenation rate is kd=0.2day−1, the reaeration rate is kr=0.4day−1, the ultimate BOD load is La=20mg/L, and the initial deficit is D0=0. If the saturation dissolved oxygen is DOsat=9.0mg/L, what is the minimum (critical) dissolved oxygen in the stream?
Worked solution
Find the critical time, then the critical deficit, then subtract from saturation. With D0=0, the critical time is tc=kr−kd1ln(kr/kd)=0.21ln(2)=3.47 days. The critical deficit is Dc=krkdLae−kdtc=0.40.2(20)e−0.2(3.47)=10(0.5)=5.0 mg/L. Minimum DO =DOsat−Dc=9.0−5.0=4.0 mg/L. The 5.0 mg/L choice reports the critical deficit itself, forgetting to subtract it from saturation. The 9.0 mg/L choice ignores the deficit entirely. The 0.0 mg/L choice wrongly drops the decay factor e−kdtc, giving Dc=10 and a negative DO clamped to zero.
Q15A rectangular primary sedimentation tank measures 80ft long by 20ft wide by 12ft deep and treats a flow of Q=1.5MGD. What is the hydraulic detention time? (Use 1ft3=7.48gal.)
Worked solution
Detention time is volume over flow: θ=V/Q. The tank volume is V=80×20×12=19,200 ft3. Convert the flow to ft3/day: Q=1,500,000gpd/7.48=200,535 ft3/day. So θ=19,200/200,535=0.0958 days =0.0958×24=2.3 hours, a typical primary clarifier value. The 0.31 hours choice forgets to divide by 7.48 (treats gallons as cubic feet). The 17.2 hours choice inverts the gallon conversion. The 0.096 choice reports the answer in days (0.096) rather than converting to hours.
Tank volume:
V=80×20×12=19,200ft3
Flow in ft3/day:
Q=7.481,500,000gpd=200,535ft3/day
Detention time:
θ=QV=200,53519,200=0.0958day
Convert to hours:
θ=0.0958×24=2.3hours
FE Reference Handbook 10.6, p. 345
Q16A circular secondary clarifier must be sized so the overflow rate does not exceed vo=900gpd/ft2 at a design flow of Q=2.5MGD. What minimum tank diameter is required?
Worked solution
Overflow rate is vo=Q/A, so the required surface area is A=Q/vo=2,500,000/900=2,778 ft2. For a circular tank A=πD2/4, so D=4A/π=4(2,778)/π=3,537=59.5 ft. The 29.7 ft choice forgets the factor of 4, computing D=A/π=29.7 ft (this is actually the radius). The 88.4 ft choice uses A=πD2 without the 1/4. The 2,778 ft choice reports the surface area itself rather than solving for the diameter.
Required surface area:
A=voQ=9002,500,000=2,778ft2
Solve the circular area for diameter:
D=π4A=π4(2,778)
Compute:
D=3,537=59.5ft
FE Reference Handbook 10.6, p. 345
Q17A chlorine contact basin holds a free residual of C=2.0mg/L, and the 10th-percentile contact time is t10=45min. What disinfection CT value is achieved?
Worked solution
CT = C × t₁₀ = 2.0 × 45 = 90 mg·min/L. The 22.5 mg·min/L choice divides instead of multiplying (45/2). The 47 mg·min/L choice adds the two values (2 + 45). The 0.044 mg·min/L choice divides C by t₁₀ (2/45) rather than multiplying.
CT relationship:
CT=C×t10
Compute:
CT=2.0×45=90mg⋅min/L
FE Reference Handbook 10.6, p. 352
Q18A filter sand has an effective size d10=0.50mm and d60=0.75mm. What is the uniformity coefficient of the media?
Worked solution
Uniformity coefficient UC = d₆₀/d₁₀ = 0.75/0.50 = 1.5. A lower UC means more uniform grain sizes. The 0.67 option inverts the ratio (d₁₀/d₆₀). The 1.25 option uses a wrong pairing. The 0.25 option subtracts the sizes.
Uniformity coefficient:
UC=d10d60=0.500.75
Compute:
UC=1.5
FE Reference Handbook 10.6, p. 347
Q19A wastewater plant receives total suspended solids of 220mg/L and must discharge at or below 30mg/L. What TSS removal efficiency is required?
Worked solution
Efficiency = (in − out)/in = (220 − 30)/220 = 190/220 = 0.864 = 86.4%. The 13.6% choice is the fraction remaining (30/220). The 30% choice reports the effluent number as a percent. The 7.3% choice inverts the ratio.
Removal efficiency:
E=220220−30×100%
Compute:
E=220190=86.4%
Q20A pump must overcome a static lift of 18m plus friction and minor losses of 6.5m while delivering Q=0.030m3/s at a pump efficiency of η=0.70. What brake power is required? (Use ρg=9,810N/m3.)
Worked solution
Total dynamic head = static + losses = 18 + 6.5 = 24.5 m. Fluid power = γQH = 9,810 × 0.030 × 24.5 = 7,210 W ≈ 7.2 kW. Brake power = 7.2/0.70 = 10.3 kW. The 7.2 kW option is the fluid power (no efficiency). The 5.3 kW option uses only the static lift (9,810 × 0.030 × 18 ≈ 5,300 W). The 5.0 kW option multiplies by 0.70 instead of dividing (7.2 × 0.70 ≈ 5.0).